Universal Quick Disconnect Couplings Supplier for Liquid Cooling
TICOOLFLOW supplies UQD manual and UQDB blind-mate quick disconnect couplings for rack manifolds, server cooling loops and modular liquid cooling assemblies. Compare series and specifications, then send your mating interface, operating conditions and quantity for project pricing. MQD / MQDB configurations are also available for review.
Select by flow, pressure drop, mating interface, coolant and seal material. Confirm the exact interface specification and revision for your project; the UQD name alone does not establish cross-brand interchangeability or compliance.
Product Range
UQD, UQDB & NVQD Liquid Cooling Coupling Range
Quick disconnect configurations for rack cooling, blind-mate modules, cold plate loops, GPU cooling, and high-density server liquid cooling systems.
UQD Manual Quick Disconnect Couplings
Standard universal quick disconnect couplings for hose-to-rack, rack-to-manifold, and liquid cooling distribution applications.
- Pressure: 6.9–20 bar by listed size
- Size: 1/8" to 1/2"
- Material: SS 316L / SS 304
- Use: Manual quick connection
UQDB Blind-Mate Quick Disconnect Couplings
Blind-mate floating quick disconnect couplings for behind-blade connections, hard-to-reach environments, and high-density server rack systems.
- Pressure: Up to 20 bar depending on size
- Misalignment: Radial compensation available
- Material: SS 316L / SS 304
- Use: Blind-mate connection
MQD / MQDB Series
Push-type fluid connectors for compact liquid cooling loops, single-hand operation, service connections, and compact cooling circuits.
- Pressure: Up to 6.9 bar depending on configuration
- Size: 1/8" to 1/2"
- Material: SS 316L / SS 304
- Use: Push-to-lock connection
UQD vs UQDB: Select a Connection for Your Cooling Assembly
Start with the connection method and available service access, then review hydraulic performance and the exact mating interface.
01 / Manual Connection
Review UQD where the coupling is accessible for connection and maintenance. Confirm release clearance, hose routing, retention and the required connection sequence.
02 / Blind-Mate Interface
Review UQDB for connections made as a module or tray is inserted. Confirm mounting arrangement, radial alignment, insertion force and engagement travel.
03 / Existing Interface
For NVQD / NVQDB or an existing supplier part, send the full part number and drawings. Size alone cannot establish mating compatibility or an approved replacement.
Include required flow, allowable pressure drop, connected and disconnected pressure, temperature, coolant formulation, seal material, end connection and quantity. Qualification should use the selected configuration’s current drawing and test requirements.
Product Videos
UQD / UQDB Quick Disconnect Demonstration Videos
Review the supplied connection and manufacturing demonstrations for data center liquid cooling components.
UQD Connection Demonstration
Demonstration of Universal Quick Disconnect connection behavior for liquid cooling applications.
Coupling Manufacturing Demonstration
Manufacturing footage supplied with the product reference; discuss your required blind-mate interface and alignment conditions.
Quick Coupling Manufacturing Process
Precision manufacturing process for stainless steel quick disconnect couplings.
UQD Technical Data
UQD Quick Disconnect Coupling Specifications
| Size | Body Size | Nominal Flow Diameter | Connected Pressure | Rated Flow | Cv Value | Air Inclusion Max | Fluid Loss Max |
|---|---|---|---|---|---|---|---|
| UQD02 | 1/8 | 3.16 mm | 20 bar / 290 psi | 2.1 lpm / 0.6 gpm | 0.33 | 0.004 cc | 0.007 cc |
| UQD04 | 1/4 | 6.3 mm | 16 bar / 232 psi | 6.4 lpm / 1.7 gpm | 1.37 | 0.024 cc | 0.01 cc |
| UQD06 | 3/8 | 7.9 mm | 6.9 bar / 100 psi | 11.4 lpm / 3.0 gpm | 2.37 | 0.027 cc | 0.022 cc |
| UQD08 | 1/2 | 10 mm | 6.9 bar / 100 psi | 17.8 lpm / 4.7 gpm | 5.32 | 0.029 cc | 0.03 cc |
UQDB Technical Data
UQDB Blind-Mate Coupling Specifications
| Size | Body Size | Nominal Flow Diameter | Connected Pressure | Burst Pressure | Rated Flow | Cv Value | Air Inclusion Max | Fluid Loss Max | Radial Misalignment |
|---|---|---|---|---|---|---|---|---|---|
| UQDB02 | 1/8" | 2.8 mm | 20 bar / 290 psi | 60 bar / 870 psi | 2.1 lpm / 0.55 gpm | 0.31 | 0.04 cc | 0.02 cc | 1 mm |
| UQDB04 | 1/4" | 5.5 mm | 16 bar / 232 psi | 48 bar / 696 psi | 6.4 lpm / 1.7 gpm | 1.22 | 0.04 cc | 0.025 cc | 1 mm |
| UQDB06 | 3/8" | 6.3 mm | 10 bar / 145 psi | 30 bar / 435 psi | 11.36 lpm / 3.0 gpm | 2.23 | 0.093 cc | 0.035 cc | 1 mm |
| UQDB08 | 1/2" | 7.9 mm | 10 bar / 145 psi | 30 bar / 435 psi | 17.8 lpm / 4.7 gpm | 3.76 | 0.096 cc | 0.044 cc | 1 mm |
Values reproduced from the supplied product reference. Burst pressure is a test reference, not a permissible working pressure. Confirm size, alignment conditions, seals and current drawings before selection.
From Rack Manifold to Server Cooling Loop
Connection choices follow system layout, service access and coolant requirements.
AI & HPC Servers
Connections between rack distribution, flexible hoses and cold plate assemblies. Review flow demand and pressure drop for the complete supply and return circuit.
Rack Manifolds & Modules
Manual service connections or blind-mate module interfaces. Confirm mounting, alignment, engagement travel and maintenance clearance.
CDU & Hose Assemblies
Review coupling size and end connections with the cooling assembly drawing. Consider hose retention, routing and the permitted isolation procedure.
Water-glycol, dielectric and other engineered coolants require separate material and seal compatibility review. Low fluid-loss figures do not imply zero spillage, and service procedures must be confirmed for the system.
Engineering Qualification for OEM & Project Procurement
Include the inspection scope and acceptance criteria in your inquiry.
Materials & Dimensions
Specify the body grade, seal compound, threads, mating dimensions and required material documentation.
Leak & Pressure Tests
Agree the test medium, pressure, temperature and acceptance limits for the selected assembly.
Flow & Service Cycles
Request available flow and pressure-drop data, connection force and cycle requirements for your project.
Universal Quick Disconnect FAQ
What is a Universal Quick Disconnect?
A UQD is a quick connection component used to connect and disconnect liquid cooling lines with controlled fluid loss and air inclusion. Select the exact mating configuration and operating limits for your system.
What is the difference between UQD and UQDB?
UQD refers here to manual connections. UQDB is a blind-mate series for module insertion and connections with limited direct access. Mounting and alignment requirements differ by configuration.
Does “universal” mean all brands are interchangeable?
No. Confirm the exact series, size, mating geometry, engagement method, materials, seals and qualification requirements before approving an alternative supplier’s part.
Which coolant and seal combinations can I request?
The supplied reference lists stainless steel body options and EPDM / FKM seals. Send the coolant formulation and concentration, temperature and pressure for compatibility review; a material name alone does not establish suitability.
How should I use the technical tables?
The tables reproduce the supplied UQD and UQDB reference data. Rated flow depends on test conditions, and burst pressure is not a working-pressure rating. Confirm the current datasheet for the exact configuration.
Can I request samples or a volume quotation for an OEM project?
Yes. Include the series, mating interface, evaluation quantity, estimated production demand and required delivery date in your inquiry. Sample availability, MOQ, documentation and lead time are confirmed for the selected configuration during quotation.
Does this page establish OCP compliance or approval?
No. If your project requires a particular OCP interface specification or other qualification, provide the document and revision. Request supporting documentation for the exact part; series names and reference performance tables do not establish compliance.
What should I include in an inquiry?
Send series, size, mating part number or drawing, coolant, operating pressure and temperature, flow and pressure-drop requirements, end connection, quantity and required inspection or qualification scope.
UQD / UQDB Supply for OEMs & System Integrators
Build your inquiry around the exact assembly and purchasing requirements. Sample availability, order quantity, delivery timing and documentation are confirmed during quotation.
Sample & Interface Evaluation
Send the mating part number, interface drawing and specification revision. Include sample quantity, test conditions and acceptance criteria for evaluation planning.
Project & Volume Quotation
Specify the required quantity, estimated project demand and target delivery schedule. Request confirmation of MOQ, availability and lead time for the selected configuration.
Assembly & Documentation Review
Provide hose or port connections, installation dimensions and required drawings, material documents and inspection records. Confirm the available scope with your quotation.
Request UQD / UQDB Project Pricing
Send your series, size, mating part number or drawing, coolant, operating conditions and quantity. Include your sample qualification requirements and target delivery date so availability and project pricing can be confirmed.